Probably not cant think of another issue. Mine just did the same. and loosing its prime . Slo puedes comparar 4 propiedades, cualquier nueva propiedad aadida reemplazar a la primera de la comparacin. Sometimes it is just a stick or debris stuck between the valve diverter (aka rotor or footpad) and the spider gasket, and a little wiggle or jiggle or repositioning of the handle can seal up the waste port, for a time If it reoccurs, this means that the spider gasket is twisted, worn or damaged. If communication between the ignition board and the display board is not established within 3 s of power-up an error will be displayed. All Products, View Check the usual spots for air coming into the pump, 1) the threaded pipe coming into the pump (did you use thread sealant? Hi Freddy, usually a clicking noise may be a relay, which are used in control systems for pools. If the pump is not grounded correctly, might that have something to do with it tripping? Chapter 1: The Evil Emperor's Son. I would turn it off and it would hum and eventually start. If it is not, re-align your flow switch. Hi Jodi, perhaps the rod is not threaded all the way into the base, or there may be debris under the rod, preventing it from going down fully. Thanks in advance! What should I do? Hi Nancy, Heat Sinks are designed to absorb the heat from the motor, and dissipate it safely. Conversely, and by the way, when pressure is much lower than normal, that indicates an obstruction before the filter, like clogged pump or skimmer baskets or an impeller clog. I filled the pool to the level line, but the air bubbles stayed. If you remove the motor from the pump, and then turn on the power very briefly if the noise continues, its the bearings, if it runs quiet (high speed), then look to vibration or cavitation. If it is still making chlorine and no real faults are flashing on the control, I wouldnt be too worried about it. The pump itself works great. The latest Lifestyle | Daily Life news, tips, opinion and advice from The Sydney Morning Herald covering life and relationships, beauty, fashion, health & wellbeing We would like to show you a description here but the site wont allow us. how to watch past broadcasts on twitch. Shock the pool first and overfilter, before pulling pump. Hi David, an air leak will always come from a point BEFORE the impeller. The pool seems to be bonded,I did find that the Aqua Logic Panel is fed from the main electrical panel has no equipment ground, when I established a ground, the motor shortly after burnt up, heard a little crakling and a pop in the motor housing, and little smoke (the breaker did not trip, until the pump smoked out it seemed to be running fine, with a normal amp load. The leak at the bottom of the pump, determine if its coming from the top of the pump and dripping down the sides, or if the leak is coming from directly under the pump, in the first case its usually the exit pipe threads are loose, and in the second case, its a leaking shaft seal or leaking drain plug, or sometimes a leaking volute o-ring, or the large o-ring between the seal plate and the pump housing. While the filter pump runs, you can here a drop for a millisecond every roughly 5 mins. If the spa is draining while in spa mode, it must be sending some water back to the pool, either the valve is not closing all the way, allowing some water to return to the pool. The correct replacement would be the AquaRite Main PCB (OEM) GLX-PCB-RITE. My Hayward mother is a 1.5 hp. Now the backwash is leaking a small amount water and the pump seems to be surging instead of running smoothly. Second be sure that you are delivering 230V (+/- 10%) and that the motor is set to accept 230V (some are reversible to accept 115V too). If not, keep reading. ), or 4) loose suction side valves, I have a hayward 1081 century with 3/4 hp motor with top mounted capacitor. For a better experience, please enable JavaScript in your browser before proceeding. Checked to make sure nothing was blocking it. My Hayward Pump Super shuts off and then starts then shuts off and then starts again. Check all the power wires for tight fit and no corrosion. Replaced the flow sensor as it seemed to run when lower RPMs on the pump and it now seems to cut it off when the RPMs on the pump drop like it should, and it will cut off when temperature reaches set heat of 93 for the spa. You may need to start shopping for a new motor and shaft seal, or a whole new pump of the same size and type. Automatic reset is immediate after error is corrected. This issue started immediately after I changed the filter grids on my FNS plus 60 filter. Thanks. It could also be that the power cord is not rated for 15 amps, which is the likely size of the breaker for the outlet (but check the breaker amp size). Product Type Model Name Select Model # I basically removed my old pump and instalked the new one. 24V after the transformer is present. I inspected the impeller and it looks fine except where the threads are there are tiny hairline fractions. Overheating can be a short across the windings, or it can be other major faults within the motor. I think I have some air leakage on my supply side of my Hayward Super Pump. What would the problem be? It appears to be stuck. Hi Patrick, so you have power from the breaker to the timer and to the switch. In my experience, a motor overheating is usually on its last legs what you could do is take it to an electric motor shop in town, and have them run it thru some diagnostics, should not be too expensive, but call first to check. Third guess is closed or broken valves, clogged filter, clogged impeller, or other obstruction preventing water flow. In particular, if the salt content of your pool water is too high, your metal screws, handrails, ladders, and covers will rust excessively. Hi Now when we try to turn everything on the pump wont start at all and keeps tripping the breaker. If yes, the motor bearings are the problem. Usually however, a howling or moaning sound from the pool heater, is low water flow. Maybe not a pump issue, but supply issue. Any advice?? Low speed should be enough flow to activate the flow switch. "@type": "Person",
If lots of air churns when you shut the pump off, and the water quickly blasts out of the pump, thats likely a suction side air leak. They dont typically make noise for long either, because at 3400 RPM, if the impeller is hitting something, it will quickly wear it down. Remove the pump and basket, then look for and remove any debris in the shaft. If you see any damage, replace your flow switch. Could this be my problem? ) and you should be able to feel debris lodged in the impeller with your fingertips. Oftentimes I reassemble the pump only to find the diffuser laying on the ground (doh!). Mine hums and then trips the breaker. Whats that part called in case I do break it? Also look for any burn marks on the wire terminal board, or any crimped wires running round the rear of the motor. Thinking its the compressor or really dont know at this point. Finally, it could be making the noise at the burner orifice, if one or more is not fully spewing gas, or is not ignited like the rest. I would suggest replacing the pump with the same exact pump, which is matched to your filter size presumably. Capacitor is a battery in the back of the motor, at 9 oclock that assists in starting the motor, if the capacitor was weak, that may draw more amps from the breaker. BUT THE BEARINGS. I replaced my old hayward maxflow pump with the new variable speed sp2670020vsp. It can also happen when voltage is incorrect (too high or too low), or when wires are shorting out, or in some cases, very hot weather and direct sunshine and other nearby sources of heat. HAYWARD SALT CHLORINATOR SYSTEM 35K - BLUE ESSENCE-35 This is wholesale site for our registered customers. Another oddity is both failure are upon Spring re-opening,and the pumps ran flawlessly throughout each summer? I just replaced the flow switch and that solved one problem, but now I'm only able to produce chlorine when the system is on Super Chlorinate. Theres no sound, when we hit the power switch no power. Is the wire the correct size wire? Another piece of information is that the board was replaced back around May of this year as well as the flow sensor. If the motor label says 115V/230V it is reversible, but if it says just 230V, Hi Chad, Gas pressure is ok. Any ideas? Hi, I have a filter timer and a cleaner timer that are side-by-side. Check wires on the other end, where they connect to the autochlor too. I will re-check all the wiring. Loose wire connections or touching terminal connections cause sparking. When we turn on power, the pump does not make noise but the timer box and the circuit box make a light humming noise and then the circuit tripped. Plate appeared to be good. Or to a light switch and then to a breaker, that would be more of a standard installation. Step 4: Verify your pumps pressure. Hi Terri, when you connect the vacuum hose to the skimmer to start vacuuming, this is like increasing the length of the pipe from the pool to the pump, which makes the pump have to work harder, kind of like drinking through a very long straw. So we cannot manually rotate the shaft a full revolution. Cleaners, Learn About And if you have Hayward heater error codes on display, that makes finding the problem almost easy! Initially, look into the pump/strainer housing. Any suggestions what it could be. I have a Hayward 1.65 variable speed pump it is on a timer for high and low. Step 3: Double check the wires on the flow switch for damage. It looks like its coming from in between the motor and pump.Am I correct in thinking I need a new seal plate kit? I replaced the breaker and electrical plug which showed some damage but motor does not start and breaker still tripping We replaced the handle assembly and valve per Hayward tech support that hasnt fixed the problem. All Products, View And make sure the bolts are tight of course. If a LED is ON, check to see if the flow switch was installed correctly. Switch your cell type by cycling the main switch from AUTO to SUPER CHLORINATE and then back to AUTO. Hi Rachel, Im guessing a Hayward Perflex DE filter? Home / Pool Equipment / Pool Pumps / Hayward Pool Pump Troubleshooting. If your new pump is the exact same make/model/horsepower as the old pump, then the pump is not the problem but if you switched make/models check the pump flow curve, because even though it may be the same hp, different make/model pool pumps produce Vastly different flow rates.